Papers, reports and book chapters published by D W O Rogers and members
of his group
Site is (always) under construction.
A publication list for D W O Rogers is available here.
Google Scholar entry is here
Back to home
page.
Monte Carlo study of ionization chamber magnetic field
correction factors as a function of angle and beam quality
Medical Physics
45 (2018) 908 -- 925
V N Malkov and D W O Rogers
RECORDS: improved Reporting of montE CarlO RaDiation
transport Studies: Report of AAPM Research Committee TG 268
Medical Physics
45 (2018) e1--e5
I Sechopoulos, D W O Rogers, M Bazalova-Carter, W E Bolch, E C Heath, M F McNitt-Gray,
J Sempau and J F Williamson
Reply to Comment on `egs_brachy: a versatile and
fast Monte Carlo code for brachytherapy'
Physics in Medicine and Biology
63 (2018) 038002(5pp)
R M Thomson, R E P Taylor, M J P Chamberland and D W O Rogers
Sensitive volume effects on Monte Carlo calculated
ion chamber response in magnetic fields
Medical Physics
44 (2017) 4854 -- 4858
V N Malkov and D W O Rogers
Published as a Medical Physics Letter
egs_brachy: a fast Monte Carlo code for brachytherapy
dose calculations
Physics in Medicine and Biology
61 (2016) 8214 -- 8231
Marc J P Chamberland, Randle E P Taylor, D W O Rogers and Rowan M Thomson
Charged particle transport in magnetic fields in
EGSnrc
Medical Physics
43 (2016) 4447 -- 4458
V N Malkov and D W O Rogers
Editor's Pick for July 2016, Open access
Monte Carlo reference data sets for imaging research:
Executive summary of the report of AAPM Research Committee Task Group 195
Medical Physics
42 (2015) 5679 -- 5691
I. Sechopoulos, E. S. M. Ali, A. Badal, A. Badano, J. M. Boone, I. S. Kyprianou,
E. Mainegra-Hing, K. L. McMillan, M. F. McNitt-Gray,
D. W. O. Rogers, E. Samei and A. C. Turner
Full TG195 report (62pp)
Towards a quantitative, measurement-based estimate of
the uncertainty in photon mass attenuation coefficients at radiation
therapy energies
Physics in Medicine and Biology
60 (2015) 1641 -- 1654
E. S. M. Ali, B. Spencer, M. R. McEwen and D. W. O. Rogers
Effect
of improved TLD dosimetry on the determination of dose rate constants
for 125I and 103Pd brachytherapy seeds
Medical Physics
41 (2014) 114301 (15pp)
M. Rodriguez and D. W. O. Rogers
Monte Carlo calculations of electron beam quality conversion factors for
several ion chamber types
Medical Physics
41 (2014) 111701 (15pp)
B. R. Muir and D. W. O. Rogers
Determination of relative ion chamber calibration coefficients
from depth-ionization measurements in clinical electron beams
Physics in Medicine and Biology
59 (2014) 5953 -- 5969
B. R. Muir, M. R. McEwen and D. W. O. Rogers
Addendum to the AAPM's TG--51 protocol for clinical reference
dosimetry of high-energy photon beams
Medical Physics
41 (2014) 041501 (20pp)
M. R. McEwen, L. A. DeWerd, G. S. Ibbott, D. S.
Followill, D. W. O. Rogers, S. M. Seltzer and J. P. Seuntjens
Monte Carlo calculations for reference dosimetry of electron beams with the
PTW Roos and NE2571 ion chambers
Medical Physics
40 (2013) 121722 (16pp)
B. R. Muir and D. W. O. Rogers
Comment on `Monte Carlo simulation on a gold nanoparticle irradiated by
electron beams'
Physics in Medicine and Biology
58 (2013) 1999 -- 2001
D. W. O. Rogers
On determining dose rate constants spectroscopically
Medical Physics
40 (2013) 011713, 10pp
M. Rodriguez and D. W. O. Rogers
Unfolding linac photon spectra and incident electron energies from
experimental transmission data, with direct independent validation
Medical Physics
39 (2012) 6585 -- 6596
E. S. M. Ali and M. R. McEwen and D. W. O. Rogers
Dosimetry of 125I and 103Pd COMS eye plaques for intraocular tumors: Report
of Task Group 129 by the AAPM and ABS
Medical Physics
39 (2012) 6161 -- 6184
Sou-Tung Chiu-Tsao, Melvin A. Astrahan, Paul T. Finger, David S.
Followill, Ali S. Meigooni, Christopher S. Melhus, Firas Mourtada, Mary
E. Napolitano, Ravinder Nath, Mark J. Rivard, D. W. O. Rogers, and
Rowan M. Thomson
Detailed high-accuracy megavoltage transmission measurements:
A sensitive experimental benchmark of EGSnrc
Medical Physics
39 (2012) 5990 -- 6003
E. S. M. Ali and M. R. McEwen and D. W. O. Rogers
An improved physics-based approach for unfolding megavoltage
bremsstrahlung spectra using transmission analysis
Medical Physics
39 (2012) 1663 -- 1675
E. S. M. Ali and D. W. O. Rogers
Beam quality conversion factors for parallel-plate ionization chambers in
MV photon beams
Medical Physics
39 (2012) 1618 -- 1631
B. R. Muir, M. R. McEwen and D. W. O. Rogers
Functional forms for photon spectra of clinical linacs
Physics in Medicine and Biology
57 (2012) 31 -- 50
E. S. M. Ali and D. W. O. Rogers
Changes in dose with segmentation of breast tissues in Monte Carlo
calculations for low-energy brachytherapy
Medical Physics
38 (2011) 4858 -- 4865
J. G. H. Sutherland, R. M. Thomson and D. W. O. Rogers
Measured and Monte Carlo calculated kQ factors: accuracy and comparison
Medical Physics
38 (2011) 4600-- 4609
B. R. Muir, M. R. McEwen and D. W. O. Rogers
Point/Counterpoint: All graduate medical physics programs should have an
original research component
Medical Physics
38 (2011) 2315 -- 2317
D. W. O. Rogers, Janelle A. Molloy, and Colin G. Orton
The central electrode correction factor for high-Z electrodes in small
ionization chambers
Medical Physics
38 (2011) 1081 -- 1088
B. R. Muir and D. W. O. Rogers
Comparison of dose calculation methods for brachytherapy of intraocular
tumors
Medical Physics
38 (2011) 306 -- 311
Mark J. Rivard, Sou-Tung Chiu-Tsao, Paul T. Finger,
Ali S. Meigooni, Christopher S. Melhus, Firas Mourtada, Mary
E. Napolitano, D. W. O. Rogers, Rowan M. Thomson and Ravinder Nath
Monte Carlo calculations of kQ, the beam quality
conversion factor
Medical Physics
37 (2010) 5939 -- 5950
B. R. Muir and D. W. O. Rogers
Modified COMS plaques for 125I and 103Pd iris melanoma
brachytherapy
Int. J. Radiat. Oncol. Biol. Phys. (Red Journal)
78 (2010) 1261 -- 1269
R. M. Thomson, K. M. Furutani, J. S. Pulido, S. L. Stafford and D. W. O. Rogers
Re-evaluation of the product of (W/e)air and the graphite
to air stopping-power ratio for 60Co air kerma standards
Physics in Medicine and Biology
55 (2010) 3577-3595
R. M. Thomson and D. W. O. Rogers
Reply to 'On the pdis correction factor for cylindrical
chambers'
Physics in Medicine and Biology
55 (2010) L17 -- L19
L. L. W. Wang and D. W. O. Rogers
A more extensive response is given
here
Monte Carlo calculated absorbed-dose energy dependence of
EBT and EBT2 film
Medical Physics
37 (2010) 1110 -- 1116
J. G. H. Sutherland and D. W. O. Rogers
Replacement correction factors for plane-parallel ion chambers
in electron beams
Medical Physics
37 (2010) 461 -- 465
L. L. W. Wang and D. W. O. Rogers
Monte Carlo dosimetry for 125I and 103Pd eye plaque
brachytherapy with various seed models
Medical Physics
37 (2009) 368 -- 376
R. M. Thomson and D. W. O. Rogers
Replacement correction factors for cylindrical ion chambers in electron
beams
Medical Physics
36 (2009) 4600 -- 4608
L. L. W. Wang and D. W. O. Rogers
Accuracy of Spencer-Attix cavity theory and calculations
of fluence correction factors for the air kerma formalism
Medical Physics
36 (2009) 4173 -- 4183
D. J. La Russa and D. W. O. Rogers
Study of the effective point of measurement for ion chambers in
electron beams by Monte Carlo simulation
Medical Physics
36 (2009) 2034 -- 2042
L. L. W. Wang and D. W. O. Rogers
Systematic uncertainties in the Monte Carlo calculation of ion chamber replacement correction factors
Medical Physics
36 (2009) 1785 -- 1789
L. L. W. Wang, D. J. La Russa and D. W. O. Rogers
The replacement correction factors for cylindrical chambers in high-energy
photon beams
Physics in Medicine and Biology
54 (2009) 1609 -- 1620
L. L. W. Wang and D. W. O. Rogers
Accuracy of EGSnrc calculations of the response of various ion chambers to
60Co beams
Medical Physics
35 (2008) 5629 -- 5640
D. J. La Russa and D. W. O. Rogers
Monte Carlo dosimetry for 125I and 103Pd eye plaque
brachytherapy
Medical Physics
35 (2008) 5530 -- 5543
R. M. Thomson, R. E. P. Taylor and D. W. O. Rogers
The associated database is available
EGSnrc Monte Carlo calculated dosimetry parameters for
192Ir and 169Yb brachytherapy sources
Medical Physics
35 (2008) 4933 -- 4944
R. E. P. Taylor and D. W. O. Rogers
The replacement correction factor for the BIPM flat cavity ion chamber and
the value of W/e
Medical Physics
35 (2008) 4410 -- 4416
L. L. W. Wang and D. W. O. Rogers
An EGSnrc Monte Carlo-calculated database of TG-43 parameters
Medical Physics
35 (2008) 4228 -- 4241
R. E. P. Taylor and D. W. O. Rogers
The associated database is available
here
More accurate fitting of 125I and 103Pd radial dose
functions
Medical Physics
35 (2008) 4242 -- 4250
R. E. P. Taylor and D. W. O. Rogers
Quantifying the effect of off-focal radiation on the output of kilovoltage
x-ray systems
Medical Physics
35 (2008) 4149 -- 4160
E. S. M. Ali and D. W. O. Rogers
Relationship between %dd(10)x
and stopping-power ratios for flattening filter free accelerators:
a Monte Carlo study
Medical Physics
35 (2008) 2104 -- 2109
G. Xiong and D. W. O. Rogers
Calculation of the replacement correction factors for ion chambers in
megavoltage beams by Monte Carlo simulation
Medical Physics
35 (2008) 1747 -- 1755
L. L. W. Wang and D. W. O. Rogers
Fifty years of AAPM involvement in radiation dosimetry
Medical Physics
35 (2008) 1418 -- 1427
G. Ibbott, C.-M. C. Ma, D. W. O. Rogers, S. Seltzer, and J. Williamson
Benchmarking EGSnrc in the kilovoltage energy range against experimental
measurements of charged particle backscatter coefficients
Physics in Medicine and Biology
53 (2008) 1511 -- 1527
E. S. M. Ali and D. W. O. Rogers
Energy spectra and angular distributions of charged particles backscattered
from solid targets
Journal of Physics D: Applied Physics
53 (2008) 055505 (9pp)
E. S. M. Ali and D. W. O. Rogers
Report of the AAPM Task Group No. 105: Issues associated with clinical
implementation of Monte Carlo-based photon and electron external beam
treatment planning
Medical Physics 34 (2007) 4818 --4853
I. J. Chetty,
B. Curran, J. Cygler, J. J. DeMarco, G. Ezzell, B. A. Faddegon,
I. Kawrakow, P. J. Keall, H. Liu, C. -M. C. Ma, D. W. O. Rogers, J.
Seuntjens, D. Sheikh-Bagheri , J. V. Siebers
Monte Carlo Study of Si Diode Response in Electron Beams
Medical Physics
34 (2007) 1734 -- 1742
Lilie L. W. Wang and D. W. O. Rogers
Benchmarking BrachyDose: Voxel based EGSnrc Monte Carlo calculations of
TG-43 dosimetry parameters
Medical Physics
34 (2007) 445 -- 457
R. E. P. Taylor, G. Yegin, and D. W. O. Rogers
Efficiency improvements of x-ray simulations in EGSnrc user-codes
using Bremsstrahlung Cross Section Enhancement (BCSE)
Medical Physics
34 (2007) 2143 -- 2154
E. S. M. Ali and D. W. O. Rogers
An experimental and computational investigation of the
standard temperature-pressure correction factor for ion chambers in
kilovoltage x rays
Medical Physics
34 (2007) 4690 -- 4699
Daniel J. La Russa, M. McEwen and D. W. O. Rogers
On the accuracy of techniques for obtaining the calibration
coefficient NK of 192Ir HDR brachytherapy sources
Medical Physics
33 (2006) 3340 -- 3347
E. Mainegra-Hing and D. W. O. Rogers
Wall correction factors, Pwall, for parallel plate
ionization chambers
Medical Physics
33 (2006) 1788 -- 1796
L. A. Buckley and D. W. O. Rogers
Wall correction factors, Pwall, for thimble ionization chambers
Medical Physics
33 (2006) 455 -- 464
L. A. Buckley and D. W. O. Rogers
Fifty years of Monte Carlo simulations for
medical physics
Physics in Medicine and Biology, 50-th anniversary special issue
51 (2006) R287 -- R301
D. W. O. Rogers
An EGSnrc investigation of the Ptp correction factor for ion chambers
in kilovoltage x-rays
Medical Physics
33 (2006) 4590 -- 4599
Daniel J. La Russa and D. W. O. Rogers
Point/Counterpoint: Scientific citation indices are useful in
evaluating medical physicists for promotion and tenure
Medical Physics
33 (2006) 1 -- 3
D. W. O. Rogers and W. R. Hendee
Monte Carlo modelling of the response of
NRC's 90Sr/90Y primary beta standard
Medical Physics 32 (2005) 3084 -- 3094
T. P. Selvam, P. R. B. Saull and D. W. O. Rogers
A Monte Carlo derived TG--51 equivalent calibration for helical tomotherapy
Medical Physics 32 (2005) 1346 -- 1153
S. D. Thomas, M. Mackenzie, D. W. O. Rogers and B. G. Fallone
Calculation of energy deposition kernels for photons and
dose point kernels for electrons
Medical Physics 32 (2005) 685 -- 699
E. Mainegra-Hing, D. W. O. Rogers and I. Kawrakow
An experimental and Monte Carlo investigation of the energy
dependence of alanine/EPR dosimetry: II. Clinical electron beams
Physics in Medicine and Biology 50 (2005) 1119 -- 1129
G. G. Zeng, M. R. McEwen, D. W. O. Rogers and
N. V. Klassen
CSnrc: correlated sampling Monte Carlo calculations using EGSnrc
Medical Physics 31 (2004) 3425 -- 3435
L. A. Buckley, I. Kawrakow and D. W. O. Rogers
Large efficiency improvements in BEAMnrc using directional
bremsstrahlung splitting
Medical Physics 31 (2004) 2883 -- 2898
I. Kawrakow, D. W. O. Rogers and B. R. B. Walters
Evidence for using Monte Carlo calculated wall attenuation and
scatter correction factors for three styles of graphite-walled ion chambers
Physics in Medicine and Biology,
49 (2004) 2491 -- 2501
J. P. McCaffrey, E. Mainegra-Hing, I. Kawrakow, K. R. Shortt and
D. W. O. Rogers
Accuracy of the Burns equation for stopping-power ratio
as a function of depth and R50
Medical Physics 31 (2004) 2961 -- 2963
D. W. O. Rogers
Point/Counterpoint: Physicists are better educated for a career in medical
physics if they graduate from a specialized medical physics graduate
program rather than from a more traditional physics graduate program
Medical Physics 31 (2004) 955 -- 957
E. B. Podgorsak and D. W. O. Rogers
An experimental and Monte Carlo investigation of the energy
dependence of alanine/EPR dosimetry: I. Clinical x-ray beams
Physics in Medicine and Biology 49 (2004) 257 -- 270
G. G. Zeng, M. R. McEwen, D. W. O. Rogers and
N. V. Klassen
Which accelerator photon beams are ``clinic-like'' for
reference dosimetry purposes?
Medical Physics 30 (2003) 1546 -- 1555
N. Kalach and D. W. O. Rogers
An EGSnrc investigation of cavity theory for ion chambers
measuring air kerma
Medical Physics 30 (2003) 1211 -- 1218
L. A. Buckley and I. Kawrakow and D. W. O. Rogers
Monte Carlo calculated correction factors for primary standards of air-kerma
Medical Physics 30 (2003) 521 -- 543
D. W. O. Rogers and I Kawrakow
Calculations for plane-parallel ion chambers
in 60Co beams using the EGSnrc Monte Carlo code
Medical Physics 30 (2003) 179 -- 189
E. Mainegra-Hing, I. Kawrakow and D. W. O. Rogers
History by history statistical estimators in the BEAM code system
Medical Physics 29 (2002) 2745 -- 2752
B. R. B. Walters, I. Kawrakow and D. W. O. Rogers
Review of ICRU Report 64: Dosimetry of
high-energy photon beams based on standards of absorbed dose to water
Physics in Medicine and Biology 47 (2002) 3663 -- 3665
D. W. O. Rogers
An invited and refereed review which is a
minority report.
A much more detailed unpublished set of comments on the
report is available here
Monte Carlo calculation of nine megavoltage photon beam
spectra using the BEAM code
Medical Physics 29 (2002) 391 -- 402
D. Sheikh-Bagheri and D. W. O. Rogers
Sensitivity of megavoltage photon beam Monte Carlo
simulations to electron beam parameters
Medical Physics 29 (2002) 379 -- 390
D. Sheikh-Bagheri and D. W. O. Rogers
Multigroup discrete ordinates modelling of 125I 6702 seed dose
distributions using a broad energy-group cross section representation
Medical Physics 29 (2002) 113 -- 124
G. M. Daskalov, R. S. Baker, D. W. O. Rogers and J. F. Williamson
Calculated and measured air-kerma response of ionization
chambers in low and medium energy photon beams
in `Recent developments in accurate radiation dosimetry,
Proc. of an Int'l Workshop', Medical Physics Publishing, Madison WI
pp69 -- 84, 2002
J. P. Seuntjens, I. Kawrakow, J. Borg, F. Hobeila and D. W. O. Rogers
Monte Carlo Techniques in Radiotherapy
Physics in Canada 58#2(2002) 63 -- 70
D. W. O. Rogers
Associated front cover of Physics in Canada
The EGSnrc System, a status report
in Advanced Monte Carlo for Radiation Physics, Particle Transport
Simulation and Applications: Proc. of the Monte Carlo 2000 Meeting
Lisbon
pages 135 -- 140, Springer, Berlin, 2001
I. Kawrakow
and D. W. O. Rogers
Monte Carlo techniques for primary standards of ionizing
radiation and for dosimetry protocols
in Advanced Monte Carlo for Radiation Physics, Particle Transport
Simulation and Applications: Proc. of the Monte Carlo 2000 Meeting
Lisbon
pages 291 -- 298, Springer, Berlin, 2001
D. W. O. Rogers
Absorbed-dose beam quality conversion factors for cylindrical
chambers in high-energy photon beams
Medical Physics 27 (2000) 2763 -- 2779
J. P. Seuntjens, C. K. Ross, K. R. Shortt and D. W. O. Rogers
Dosimetric Modeling of the MicroSelectron High-Dose
Rate $^{192}$Ir Source by the Multigroup Discrete Ordinates Method
Medical Physics 27 (2000) 2307 -- 2319
G. M. Daskalov, R. S. Baker, D. W. O. Rogers and J. F. Williamson
Two-Dimensional Discrete Ordinates Photon Transport
Calculations for Brachytherapy Dosimetry Applications
Nuclear Science and Engineering 134(2000) 121 -- 134}
G. M. Daskalov, R. S. Baker, R. C. Little, D. W. O. Rogers and J. F. Williamson
Comparison of measured and Monte Carlo calculated dose
distributions from the NRC linac
Medical Physics 27 (2000) 2256 -- 2266
D. Sheikh-Bagheri, D. W. O. Rogers, C. K. Ross and J. P. Seuntjens
Monte Carlo study of correction factors for Spencer-Attix
cavity theory at photon energies at or above 100 keV
Medical Physics 27 (2000) 1804 -- 1813
J. Borg, I. Kawrakow, D. W. O. Rogers and J. P. Seuntjens
Questions for comparison of clinical Monte Carlo codes
Proceedings of XIIIth Internationl Conf on the Use of Computers in
Radiotherapy (2000) 120 --122
D. W. O. Rogers and R Mohan
For digital data related to these benchmarks,
see here
Monte Carlo simulation of a typical 60Co therapy source
Medical Physics 26 (1999) 2494 -- 2502
G. Mora, A. Maio and D. W. O. Rogers
Spectra and Air-Kerma Strength for Encapsulated 192Ir
Sources
Medical Physics 26 (1999) 2441 -- 2444
J. Borg and D. W. O. Rogers
AAPM's TG--51 Protocol for Clinical Reference Dosimetry of
High-Energy Photon and Electron Beams
Medical Physics 26 (1999) 1847 -- 1870
P. R. Almond, P. J. Biggs, B. M. Coursey, W. F.
Hanson, M. S. Huq, R. Nath and D. W. O. Rogers
High resolution versions of figures from TG51
Monte Carlo investigation of electron beam output factors
vs size of square cutout
Medical Physics, 26 (1999) 743 -- 750
G. G. Zhang, D. W. O. Rogers, J. E. Cygler and T. R. Mackie
Corrected relationship between %dd(10)x and
stopping-power ratios
Medical Physics, 26 (1999) 538 -- 540
D. W. O. Rogers and C. L. Yang
Correcting for electron contamination at dose maximum in photon beams
Medical Physics, 26 (1999) 533 -- 537
D. W. O. Rogers
A new approach to electron beam reference dosimetry
Medical Physics 25 (1998) 310 -- 320
D. W. O. Rogers
Effects of changes in stopping-power ratios with field size on
electron beam relative output factors
Medical Physics 25 (1998) 1711 -- 1724
G. G. Zhang, D. W. O. Rogers, J. E. Cygler and T. R. Mackie
Accurate characterization of Monte Carlo calculated
electron beams for radiotherapy
Medical Physics 24 (1997) 401 -- 416
C-M. Ma, B. A. Faddegon, D. W. O. Rogers and T. R. Mackie
Mean energy, energy-range relationship and
depth-scaling factors for clinical electron beams
Medical Physics 23 (1996) 361 -- 376
G. X. Ding, D. W. O. Rogers and T. R. Mackie
BEAM: A Monte Carlo code to simulate radiotherapy treatment
units
Med Phys 22 (1995) 503 -- 524
D W O Rogers, B A Faddegon, G X Ding, C-M Ma, J Wei and T R
Mackie
Winner of
2005 Informal COMP Citation Award
Ionizing Radiation Dosimetry and Medical Physics
Physics in
Canada, Special Issue, Vol 51(#4) 1995, 178 -- 181
D. W. O. Rogers
Electron mass scattering powers: Monte Carlo and analytical
calculations
Medical Physics 22 (1995) 531-541
X. A. Li and D. W. O. Rogers,
Reducing Electron Contamination for Photon-Beam-Quality Specification
Medical Physics, 21 (1994) 791 -- 798
X. A. Li and D. W. O. Rogers
The calibration and use of plane-parallel ionization chambers for dosimetry
of electron beams: An extension of the 1983 AAPM protocol report of
AAPM Radiation Therapy Committee Task Group No. 39
Medical Physics, 21 (1994) 1251 -- 1260
P. R. Almond, F. H. Attix, S. Goetsch, L. J. Humphries, H. Kubo, R.
Nath and D. W. O. Rogers
Towards a Dosimetry System Based on Absorbed-Dose Standards
in ``Proceedings of the IAEA International Symposium
on Measurement Assurance in Dosimetry '' (IAEA, Vienna)(1994) 565 -- 580
D. W. O. Rogers, C. K. Ross, K. R. Shortt,
N. V. Klassen and A. F. Bielajew
Beam quality specification for photon beam dosimetry
Medical Physics , 20 (1993) 1181 -- 1188
A. Kosunen and D. W. O. Rogers
Wall correction and absorbed dose conversion factors for Fricke dosimetry:
Monte Carlo calculations and measurements
Medical Physics , 20 (1993) 283 --292
C.-M. Ma, D. W. O. Rogers, K. R. Shortt, C. K. Ross, A. E.
Nahum and A. F. Bielajew
Comparisons of thick-target bremsstrahlung calculations
by EGS4 and ITS
Nucler Instruments and Methods , A327 (1993) 556 -- 565
B. A. Faddegon and D. W. O. Rogers
Re-evaluation of the total stopping power of polystyrene for 5.3 MeV
electrons
Physics in Medicine and Biology, 37 (1992) 969 -- 983
D. W. O. Rogers and B. A. Faddegon
Implications of new correction factors on primary air kerma standards in
up>^{60Co beams}
Physics in Medicine and Biology, 37 (1992) 1283 -- 1291
A. F. Bielajew and D. W. O. Rogers
The advantages of absorbed-dose calibration factors
Medical Physics 19 (1992) 1227 -- 1239
D. W. O. Rogers
The role of Monte Carlo simulation of electron transport in radiation
dosimetry
Int'l J. Appl. Radiation and Isotopes 42 (1991) 965 -- 974
D. W. O. Rogers
Calculation of water/air stopping-power
ratios using EGS4 with explicit treatment of electron - positron
differences
Medical Physics 18 (1991) 1222 - 1228
C. Malamut, D. W. O. Rogers and A. F. Bielajew
Wall attenuation and scatter corrections for ion chambers:
measurements versus calculations
Physics in Medicine and Biology, 35 (1990) 1065 --
1078
D. W. O. Rogers and A. F. Bielajew
The Role of Humidity and Other Correction Factors in the AAPM TG--21
Dosimetry Protocol
Medical Physics 15 (1988) 40 -- 48
D. W. O. Rogers and C. K. Ross
Calculation of Electron Contamination in a 60Co Therapy
Beam
in ``Proceedings of the IAEA International Symposium on Dosimetry in
Radiotherapy'' (IAEA, Vienna), Vol 1 (1988) 303 -- 312 (scanned 1.7Mbyte)
D. W. O. Rogers, G. M. Ewart, A. F. Bielajew and G. van Dyk
Generation of energy deposition kernels
using the EGS Monte Carlo code
Physics in Medicine and Biology 33 (1988) 1-20
T. R. Mackie, A. F. Bielajew, D. W. O. Rogers and J. J. Battista
PRESTA: The Parameter Reduced Electron-Step Transport Algorithm for
electron Monte Carlo transport
Nuclear Instruments and Methods B18 (1987) 165 -- 181
A. F. Bielajew and D. W. O. Rogers
Differences in Electron Depth Dose Curves Calculated with EGS and ETRAN and
Improved Energy Range Relationships
Medical Physics 13 (1986) 687 -- 694
D. W. O. Rogers and A. F. Bielajew
The Dependence of Mass Energy Absorption Coefficient Ratios on Beam
Size and Depth in a Phantom
Medical Physics 13 (1986) 496 -- 502
J. R. Cunningham, M. Woo, D. W. O. Rogers and A. F. Bielajew
Ion chamber response and Awall correction factors in
a 60Co beam by Monte Carlo simulation
Physics in Medicine and Biology 30 (1985) 429 -- 443
D. W. O. Rogers, A. F. Bielajew and A. E. Nahum
Monte Carlo simulation of ion chamber response to 60Co
-- Resolution of anomalies associated with interfaces
Physics in Medicine and Biology 30 (1985) 419 -- 428
A. F. Bielajew, D. W. O. Rogers and A. E. Nahum
Fluence to Dose Equivalent Conversion Factors Calculated
with EGS3 for Electrons
from 100 keV to 20 GeV and Photons
from 20 keV to 20 GeV
Health Physics 46 (1984) 891 -- 914 (scanned pdf, 3.7Mbyte)
D. W. O. Rogers
Low energy electron transport with EGS
Nuclear Instruments and Methods 227 (1984) 535 -- 548
D. W. O. Rogers
A Measurement of Absorbed Dose to Water per Unit Incident 7 MeV Photon
Fluence
Physics in Medicine and Biology 29 (1984) 1555 -- 1570
H. Mach and D. W. O. Rogers
A Nearly Mono-Energetic 6 to 7 MeV Photon Calibration Source
Health Physics 45 (1983) 127 -- 137 (scanned pdf, 890kbyte)
D. W. O. Rogers
More realistic Monte Carlo calculations of photon detector response
functions
Nuclear Instruments and Methods 199 (1982) 531 -- 548
D. W. O. Rogers
Why Not to Trust a Neutron Remmeter
Health Physics 37 (1979) 735 -- 742 (scanned pdf, 2.5Mbyte)
D. W. O. Rogers
Analytic and Graphical Methods for Assigning Errors to Parameters in
Non-Linear Least Squares Fitting
Nuclear Instruments & Methods 127 (1975) 253 -- 260
D. W. O. Rogers
Energy Resource Requirements of a Solar Heating System
Energy 5 (1980) 75 -- 86
D. W. O. Rogers
Errors in a Risk Assesment of Renewable Resources
Energy 5 (1980) 101 -- 103
D. W. O. Rogers and R. J. Templin
The three particle structure of 19F
Nuclear Physics A207 (1973) 465 -- 485
D. W. O. Rogers
Based on PhD Thesis
New High Spin States in 19F and a Possible K = 3/2+ Band
Phys. Rev. Lett. 27 (1971) 1460 -- 1463
W. R. Dixon, R. S. Storey, J. H. Aitken,
A. E. Litherland and D. W. O. Rogers
The very first paper
Discovery of the 11/2+ level in 19F
Physics Letters B (1969) 653 -- 655
J. H. Aitken, K. W. Allen, R. E. Azuma,
A. E. Litherland and D. W. O. Rogers
General characteristics of radiation dosimeters and
a terminology to describe them
Clinical Dosimetry Measurements in Radiotherapy (AAPM 2009 Summer School)
(2009) 137 -- 145
D. W. O. Rogers
The physics of the AAPM's TG-51 protocol
Clinical Dosimetry Measurements in Radiotherapy (AAPM 2009 Summer School)
(2009) 239 -- 296
D. W. O. Rogers
Stopping-power ratios, ratios of mass eneregy absorption
coefficients and CSDA ranges of electrons
Clinical Dosimetry Measurements in Radiotherapy (AAPM 2009 Summer School)
(2009) 1083 -- 1102
D. W. O. Rogers
Monte Carlo applications in measurement dosimetry
Clinical Dosimetry Measurements in Radiotherapy (AAPM 2009 Summer School)
(2009) 147 -- 180
J. Seuntjens and D. W. O. Rogers
Monte Carlo simulations: efficiency improvement techniques and statistical
considerations
Proc of AAPM 2006 Summer School: Integrating New
Technologies into the Clinic:
Monte Carlo and Image-Guided Radiation
Therapy
(2006) 71 -- 91
D. Sheikh-Bagheri, I. Kawrakow, B. Walters
and D. W. O. Rogers
Fundamentals of Dosimetry based on Absorbed-Dose Standards
Proc of
AAPM 1996 Summer School: Teletherapy Physics, Present and Future
(1996)
319 -- 356
D. W. O. Rogers
Fundamentals of High Energy x-ray and Electron Dosimetry Protocols
Proc of
AAPM 1990 Summer School: Advances in Radiation Oncology Physics: Dosimetry,
Treatment Planning and Brachytherapy
(1992)
181 -- 223
D. W. O. Rogers
Monte Carlo Techniques of Electron and Photon Transport for Radiation
Dosimetry
from "The Dosimetry of Ionizing Radiation, Vol III" edited by
Kase, Bjarngard and Attix, Academic Press, 1990 p427 - 539
D. W. O. Rogers and A. F. Bielajew
(revised Jan 10, 2014 to remove typos from scanning)
Data for an accurate transmission measurement benchmark
Carleton Laboratory for Radiotherapy Physics Report CLRP 12-02
June 2012
E. S. M. Ali, M. R. McEwen and D. W. O. Rogers
Validation of a new spectral functional form
Carleton Laboratory for Radiotherapy Physics Report CLRP 11-01
November 2011
E. S. M. Ali and D. W. O. Rogers
Monte Carlo calculations of the beam quality conversion factor,
kQ, for cylindrical iononization chambers
Carleton Laboratory for Radiotherapy Physics Report CLRP 10-02
Final version, July 2010 after Mu11 published (minor caption edits June
2013
B. R. Muir and D. W. O. Rogers
Manual of backscatter_clrp: An EGSnrc user-code for backscatter
calculations
Carleton Laboratory for Radiotherapy Physics Report CLRP 08-01
February
2008
E. S. M. Ali and D. W. O. Rogers
Inclusion of Bragg-Gray stopping-power ratios in
the EGSnrc user-code SPRRZnrc
Carleton Laboratory for Radiotherapy Physics Report CLRP 06-01
June
2006 (revised July 08)
T. P. Selvam and D. W. O. Rogers
Update of BEAMDP multiple source modelling capabilities
Carleton Laboratory for Radiotherapy Physics Report CLRP 06-02
October
2006
Zdenko Sego and D. W. O. Rogers
60Co phase-space files generated using BEAMnrc
Carleton Laboratory for Radiotherapy Physics Report CLRP 09-01
June
2009
B Muir and G. Xiong, T. Palani Selvam and D. W. O. Rogers
For EGSnrc related manuals, see
http://www.nrc-cnrc.gc.ca/eng/solutions/advisory/egsnrc_index.html
For BEAMnrc related manuals, see
http://www.nrc-cnrc.gc.ca/eng/solutions/advisory/beam_index.html
The 2003 revision of the NRC standard for
air-kerma in a 60Co beam
NRC Report PIRS-876
Oct 2003
D. W. O. Rogers and John McCaffrey
Spencer-Attix water to air mass collision
stopping power ratios as a function of depth and beam quality,
R50
NRC Report PIRS-719
June 2000
D. W. O. Rogers
Monte Carlo estimates of %dd(10)x for the NPL photon beams
NRC Report PIRS-659rev
June 2000
B.R.B. Walters and D. W. O. Rogers
Monte Carlo Calculations of Photon Spectra in Air from 192Ir Sources
NRC Report PIRS-629r
March 1999
J. Borg and D. W. O. Rogers
Monte Carlo calculated wall and axial non-uniformity
corrections for primary standards of air kerma
NRC Report PIRS-663
May 1999
D. W. O. Rogers and J. Treurniet
Monte Carlo Study of Effects of Phantom Size, Radial Position, and Depth on
Photon Beam Calibration
NRC Report PIRS-507
Aug 1995
A. Booth and D. W. O. Rogers
Energy spectra, angular spread and dose distributions of electron beams
from various accelerators used in radiotherapy.
or
html version with digital data in tables
NRC Report PIRS-439
1995
G. X. Ding and D. W. O. Rogers
History, overview and recent improvements of EGS4
NRC Report PIRS-436
June 1994
A F Bielajew, H Hirayama, W R Nelson and D. W. O. Rogers
Uncertainties in the 60Co graphite to air stopping-power ratio and a
re-evaluation of (W/e) air values
NRC Report PIRS-363
April 1993
D. W. O. Rogers
Use of ICRU-37/NBS Radiative Stopping Powers in the EGS4 System
NRC Report PIRS-177
March 1989
D. W. O. Rogers, S. Duane, A. F. Bielajew and W. R. Nelson
Use of ICRU-37/NBS Collision Stopping Powers in the EGS4 System
NRC Report PIRS-173
March 1989
S. Duane, A. F. Bielajew and D. W. O. Rogers
The Use of EGS for Monte Carlo Calculations in Medical Physics
Lecture notes for refresher course at First Inter-American Meeting of
Medical Physics, July 1984
NRC Report PXNR-2692
June, 1984
D. W. O. Rogers and A. F. Bielajew
Why to use TG-51
Interactions (COMP Newsletter) 46#3 (2000) 106--107
D. W. O. Rogers
NSERC opening up to Medical Physics
Interactions (COMP Newsletter) 56#3 (2010) 89 -- 91
D. W. O. Rogers and William Whelan
Notes on the structure of radiotherapy depth-dose distributions
Carleton Physics Report CLRP-07-01
D. W. O. Rogers
Updated Jan 25 2012