Titles: TPCA
=============
Contact: J. Cameron Oxford
Revision History:-
================
3.01 N. West First version.
4.02 J. Cameron Update.
Titles Files
------------
pca_data.dat
Verification
------------
Description
-----------
These banks contains data for the PCA processor. There are 3 banks:-
TPCA 1 Overall Control
TPCA 2/3/4 2:Gain 3:Walk version 1 4:Walk verion 2
The TPCA 1 Titles Bank
This bank selects the type of calibration, the laserball position and the
validity range of the generated constants.
Data Words
---------
Data types: B(bit), I, F, D(double), H(hollerith 4 char)
Fixed length Database Header. See titles_dbhdr.html.
Wd Typ Mnem Adr Description
KTPCA...
1 I _CAL_TYPE = 1 (= $pca_gain_cal) gain calibration
= 2 (= $pca_wkv1_cal) walk version 1 calibration
= 3 (= $pca_walk_cal) walk version 2 calibration
2 I _ADD_OLD = 0 generate all new constants
= 1 obsolete - supplement current constants
3 I _LRBP_MODE = 1 (= $lrbp_perm) use perm banks to get laserball data
= 2 (= $lrbp_ttl) get the laserball data from this bank
4 I _VAL_MODE = 1 (= $pca_rel_validity) use relative time for validity ranges
= 2 (= $pca_abs_validity) use absolute time for validity ranges
5 I _VDATE_START = Start date if using absolute validity ranges
6 I _VTIME_START = Start time if using absolute validity ranges
7 I _VDATE_END = End date if using absolute validity ranges
8 I _VTIME_END = End time if using absolute validity ranges
9 I _MPLP_MODE = 0 All channels are calibrated
= 1 PMT Mask is taken from the MPLP bank
10 I _TCORR_MODE = 0 No light-time-of-flight correction is made
= 1 Correct ToF for off-center laserball positions
11 F _VDAYS_AFTER = Number of days after calibration start date/time
if using relative validities
12 F _VDAYS_BEFORE = Number of days before calibration start date/time
if using relative validities
13 F _LRBP1_X = The x coordinate of the 1st laserball position
14 F _LRBP1_Y = The y coordinate of the 1st laserball position
15 F _LRBP1_Z = The z coordinate of the 1st laserball position
16 F _LASER_DX = The error on the x position
17 F _LASER_DY = The error on the y position
18 F _LASER_DZ = The error on the z position
19 F _LASER_WAVE = The wavelength
20 F _LRBP2_X = The x coordinate of the 2nd laserball position
21 F _LRBP2_Y = The y coordinate of the 2nd laserball position
22 F _LRBP2_Z = The z coordinate of the 2nd laserball position
23 F _LRBP3_X = The x coordinate of the 3rd laserball position
24 F _LRBP3_Y = The y coordinate of the 3rd laserball position
25 F _LRBP3_Z = The z coordinate of the 3rd laserball position
26 F _LRBP4_X = The x coordinate of the 4th laserball position
27 F _LRBP4_Y = The y coordinate of the 4th laserball position
28 F _LRBP4_Z = The z coordinate of the 4th laserball position
29 F _LRBP5_X = The x coordinate of the 5th laserball position
30 F _LRBP5_Y = The y coordinate of the 5th laserball position
31 F _LRBP5_Z = The z coordinate of the 5th laserball position
32-36 I _RUN_LRBP1 = Run numbers for the 1st laserball position
37-41 I _RUN_LRBP2 = Run numbers for the 2nd laserball position
42-46 I _RUN_LRBP3 = Run numbers for the 3rd laserball position
47-51 I _RUN_LRBP4 = Run numbers for the 4th laserball position
52-56 I _RUN_LRBP5 = Run numbers for the 5th laserball position
The TPCA 2 and TPCA 3 Titles Banks
These banks control the specific calibration. TPCA 2 for gain, TPCA 3 for
walk version 1 and TPCA 4 for walk version 2. They have the same structure.
Data Words
---------
Data types: B(bit), I, F, D(double), H(hollerith 4 char)
Fixed length Database Header. See titles_dbhdr.html.
Wd Typ Mnem Adr Description
KTPCA...
1 I _BASE Base ID for output hbook data
4-5 I Spare
5-10 F Spare
Fit constants.
11 F _FC_1 Fitting constant 1.
12 F _FC_2 Fitting constant 2.
13 F _FC_3 Fitting constant 3.
14 F _FC_4 Fitting constant 4.
15 F _FC_5 Fitting constant 5.
16 F _FC_6 Fitting constant 6.
17 F _FC_7 Fitting constant 7.
18 F _FC_8 Fitting constant 8.
19 F _FC_9 Fitting constant 9.
20 F _FC_10 Fitting constant 10.
Fit parameters.
21 F _FP_1 Fit parameter 1.
22 F _FP_2 Fit parameter 2.
23 F _FP_3 Fit parameter 3.
24 F _FP_4 Fit parameter 4.
25 F _FP_5 Fit parameter 5.
26 F _FP_6 Fit parameter 6.
27 F _FP_7 Fit parameter 7.
28 F _FP_8 Fit parameter 8.
29 F _FP_9 Fit parameter 9.
20 F _FP_10 Fit parameter 10.
Go Back to the