TFTK: Energy fitter control


                              Titles:  TFTK:  Energy fitter control
                              =====================================
 
    Contact:  M. Dunford, Penn
 
    Revision History:-
    ================
 
    5.00  M. Dunford   First version.
    5.01  M. Dunford   Added several words to bank
    5.02  M. Dunford   Added PT flag word
 

 
Titles Files
------------
 
fitter_ftk.dat
 
 
Verification
------------
 
 
Description
-----------
 
    This bank contains input data for the energy fitter. 
 
 
Data Words
---------
 
        Data types: B(bit), I, F, D(double), H(hollerith 4 char)
 
        Fixed length Database Header.  See titles_dbhdr.html.
 
        KTFTK...

   1  F _C_AVG                Speed of light used by the energy fitter      
   2  I _PRINT_MODE           Printing mode (0 = no output, 1 = verbose output)
   3  I _SEED_LVL             Fitter used for event position, direction, time
   4  I _MINIMIZE_STRATEGY    Minimization routine (1-minuit, 2-brent's method)
   5  F _BRENT_TOL            Tolerance used for Brent's method
   6  I _SCAT_BOMB_NUM        Number of photons in scattering bomb
   7  I _PMT_BOMB_NUM         Number of photons in PMT reflection bomb
   8  I _AV_BOMB_NUM          Number of photons in AV bombs
   9  F _TIM_LCUT             Lower time residual cut
   10 F _TIM_HCUT             Upper time residual cut
   11 F _NOISE_DEFAULT        Default PMT noise rate
   12 I _ENABLE_GEO           Enables GEO code for data source runs
   13 F _ITER_TOL             Tolerance used of direct photon dir. iteration
   14 F _LH_BIAS_CORR         Energy shift applied to correct for LH bias
   15 F _PMT_REFL_NORM        PMT reflection normalization factor
   16 F _3DPMT_NORM           Normalization term accounting for 3dpmt and 
                              laserball PMT response differences
   17 F _SCAT_COR             Correction to scattering calc. to account
                              for second order effects
   18 F _FID_CUT              Fiducial Volume cut
   19 I _PMT_TIMES            PT Vs. PT1 Times: 
                              = 0 Use PT1 times
                              != 0 Use PT times
20-22 I                       Spares 



Go Back to the Snoman Companion Top Page