titles_tfte
Titles: TFTE
=============
Contact: S. Brice, Oxford.
Titles Files
------------
fitter.dat
Verification
------------
Description
-----------
This bank contains input data for the elastic fitter.
Data Words
----------
Fixed length Database Header. See titles_dbhdr.html
KFTE_
1 I MIN_PMT Minimum number of PMTs to fit.
2 I TX_TYP Type of fitter to use for initial vertex position:
0 = true
1 = quad fitted
2 = time fitted
3 = origin (0,0,0)
4 = grid fitted
3 I DIR_TYP Type of fitter to use for initial vertex direction:
0 = true
1 = time fitted
2 = calculate mean direction
POSITION FIT PARAMETERS
4 F INI_P_TMP Starting temperature for position energy minimisation
by simulated annealing.
5 F FIN_P_TMP Finishing temperature for position energy minimisation.
6 F GRD_P_TMP Multiplicative factor by which position temperature
is reduced on each iteration.
7 F P_LMD Squared distance beyond which a hit is considered as noise
8 F P_DLT Attempted correction for fitter pull
9 F ETA_POS The position update parameter for gradient descent.
10 F ETA_TIM The time update parameter for gradient descent.
11 F GRD_P_ETA Multiplicative factor by which the position and time
update parameters are reduced on each iteration.
DIRECTION FIT PARAMETERS
12 F INI_D_TMP Starting temperature for direction energy minimisation
by simulated annealing.
13 F FIN_D_TMP Finishing temperature for direction energy minimisation.
14 F GRD_D_TMP Multiplicative factor by which direction temperature
is reduced on each iteration.
15 F D_LMD Squared distance beyond which a hit is considered as noise
16 F ETA_THE The polar angle update parameter for gradient descent
17 F ETA_PHI The azimuthal angle update parameter for gradient descent
18 F GRD_D_ETA Multiplicative factor by which the angle update
parameters are reduced on each iteration.
19 I MAX_ITER Maximum number of iterations allowed
20 F TOL Fractional tolerance on the position and direction
minimisations
Go Back to the