TCAC: Time Correlation Analyser: Control
Titles: TCAC: Time Correlation Analyser: Control
=================================================
Contact: N. West, Oxford.
Revision History:-
================
3.01 N. West First version.
Titles Files
------------
tca_demo_titles.dat
Verification
------------
Description
-----------
This bank controls the Time Correlation Analyser (TCA). For more
information see the Time Correlation Analyser chapter in the SNOMAN User's
Manual.
Data Words
---------
Data types: B(bit), I, F, D(double), H(hollerith 4 char)
Fixed length Database Header. See titles_dbhdr.html
Word Type Mnemonic [symbolic command] Description
---- ---- -------- -------------------------------
KTCAC...
1 I _BUFFER_FRAC [tca_buffer_frac] Fraction of the avaliable free
memory TCA can grab. If TCA is running as the only
processor, leave this at its default of 1.0
2 I _QUIT_ON_OVFL [tca_quit_on_ovfl] Flag:
= 0 This is the default and tells TCA to continue
even though data will be lost. The output log will
give an estimate of the size of buffer needed to
prevent the
= 1 abort if buffer overflow.
3 I _AMBIG_MAX [tca_ambig_max] Defines maximum possible ambiguity
(the number of times a given primary can form
associations with different secondaries) that TCA
will encounter. This defines the size, in records, of
the output buffer that has to hold them.
4 I _AMBIG_REQ [tca_ambig_req] Defines maximum ambiguity TCA is to
output. By using the _SORT_ON variable to measure
the quality of the association together with this
command, the user can output just the best
associations.
5 I _OUTPUT_UNASS [tca_output_unass] Flag:
= 0 Don't output unassociated primaries
= 1 This tells TCA to output a primary even if it
fails to form an association. Such n-tuple entries
have the undefined value for any variable that
depends directly or indirectly on any event other
than the primary.
6 I _TIME_GATE_LOW [tca_time_gate_low] Selects the low edge of the time
gate. Any event occurring at a time earlier than
this, relative to the current primary, will not form
an association in which the current event is the
primary. The lower limit must be less than zero.
7 I _TIME_GATE_HIG [ca_time_gate_high] Selects the high edge of the time
gate. Any event occurring at a time later than this,
relative to the current primary, will not form an
association in which the current event is the
primary. The higher limit must be greater than zero.
Go Back to the