titles_pmtt
Titles: PMTT
=============
Contact: D. Wark, Oxford.
Titles Files
------------
pmt_response.dat
Verification
------------
Description
-----------
This bank contains the data on the PMT timing and noise performance.
Data Words
----------
Fixed length Database Header. See titles_dbhdr.html
**For PMTT 1 (Information generic to all models)
This bank is mapped into common
Line Variable [Symbolic Command] Description
---- -------- ------------------------------
1 T_TRANSIT Average transit time accross tube
2 TJITT Variance of the transit time spread distribution (ns)
See warning.
3 TNOIS [pmt_nois_rate] Mean PMT noise rate in Hz.
Warning
=======
TJITT is no longer used in the simulation of the PMT response, since that is
now represented by a skewed Gaussian function. Still, we require to assume
something for fitters in order to compute a chi-squared, so TJITT has been
retained for that purpose, as an "equivalent symmetric gaussian" of the current
model.