NQNH: NCD Global Event Header
Titles: NQNH: NCD Global Event Header
=====================================
Contact: Mark Howe / Jan Wouters / Adam Cox
Version 2 verified on 10-29-04 by LCS and KRR
Revision History:-
================
2003-02-11 (jmw) - Original
2003-11-20 (gac) - Added ORCA_VERS and changed all entries to integers
2003-11-22 (jmw) - Added NQHN_RUN_TYPE. Fixed parameter lengths.
2004-07-12 (krr) - Added Trigger Options
Titles Files
------------
Verification
------------
Description
-----------
Bank Number: 2
Written out at the beginning of a run by ORCA. Contains basic
run information.
Data Words
----------
Fixed length Database Header. See titles_dbhdr.html
Data types: B(bit), I, F, D(double), H(hollerith 4 char)
Word Type Mnemonic Description
1 I NQNH_VERS NQNH bank version number
2 H NQNH_DATA_VERS Version number of the data
3 H NQNH_ORCA_VERS Orca code version number
4 I NQNH_RUN Run number #
5 I NQNH_TIME Start of run time in seconds since #
6 I NQNH_RUN_TYPE Run Mask -- Bits are:
0 = NEUTRINO
1 = SOURCE
2 = CALIBRATION
3 = NCD PHASE
4 = SALT PHASE
5 = POISON
6 = PARTIAL FILL
7 = AIR FILL
8 = D2O
9 = H2O
10 = UC BIT
11 = TRANSITIONAL
12 = SOURCE MOVING
13 = COMP. COILS
14 = PMT ECA
15 = DIAGNOSTIC
16 = SUPERNOVA
17 = PMT MAINTENANCE
18 = PCA
19 = EXPERIMENTAL
20 = D20 CIRC.
21 = BUBBLERS
22 = S. L. ASSAY
23 = NCD MAINTENANCE
24 = MTC/PMTs OFF
25 = NCDs OFF
26 = NCD CALIBRATION
7 I NQNH_TRIG Trigger options (Bits are:
0 = Shipping Evt1 Clk (Mux)
1 = Shipping Evt2 Clk (Shaper)
2 = Use Software GtId
3 = Use Mux Shaper Association (M-SAM)
4 = Use No Hardware
5 = 10MHz Clock Enabled
6 = Trigger1 Gt Only
7 = Trigger2 Gt Only
8 = Trigger2 Event Input Enabled
9 = Trigger2 Busy Enabled
10 = LiveTime Counters Enabled
Go Back to the
Snoman Companion Top Page