titles_mcec
Titles: MCEC
=============
Contact: D. Wark, Oxford.
Revision History:-
================
3.00 D. Wark First version.
Titles Files
------------
mc_generator.dat
Verification
------------
Description
-----------
This bank controls the simulation of the electronics calibration.
Data Words
----------
Fixed length Database Header. See titles_dbhdr.html
Line Type Variable Description
---- ---- -------- -----------
1 I EC_FIRST Lowest tube to calibrate.
2 I EC_TYPE Type of cal (1=ped., 2=t slope, 3= q slope)
3 I EC_GROUPS Number of groups of tubes.
4 I EC_NTUBES Number of tubes in each group.
5 I EC_NPULSES Number of pulses in each channel.
6-8 F EC_T_PED Param. for t pedestal dist. (see EC_dT)
9-14 F EC_T_PAR Param. for t slope dist. (see EC_dT)
15-23 F EC_Q_PED Param. for q pedestal. (see EC_dQ)
23-34 F EC_Q_PAR Param. for q slope dist. (see EC_dQ)
34 F Pulser Freq Pulser rate (Hz).
Go Back to the