How To use MAGBOLTZ

 

Installing MAGBOLTZ
The MAGBOLTZ program is currently installed in ~gmd/garfield To install MAGBOLTZ first download the FORTRAN file from here and compile in a directory of your choice.

g77 -o magboltz.run magboltz.f -L/local/cern/pro/lib -lpacklib -lmathlib -lkernlib

MAGBOLTZ Results
To view some results for various gas mixtures from Magboltz click here.
To view calculations of drift distances for ArCO2 90/10 and 80/20 click here or to download/view the data file --> (OpenOffice - Excel)

Input Cards
The parameters are set in an input file (for example: magboltz.input) and read in by the program. Each line of this file is an input card.
Formatting refers to the amount of space reserved for each variable in that line, for example if the format is 2I10 and the values you want to enter are "2" and "10", then you would need to write 2 followed by nine spaces, then 10 followed by eight spaces. You do not need to include spaces at the end of a line.

Note: the format syntax is the same at that of FORTRAN, in this case 2I10 means two integers with ten place holders each.

First Card
Format: 2I10,F10.5, variables: NGAS,NMAX,EFINAL

NGAS number of gases in mixture
NNMAX number of real collisions (multiple of 10**7), use a value between 2 and 5 for inelastic gas to obtain 1 % accuracy, use a value above 10 for better than 0.5 % accuracy and a value of at least 10 for pure elastic gases like Argon
NEFINAL upper limit of the electron energy in electron Volts, if EFINAL = 0.0, program automatically calculates upper integration energy limit

Second Card
Format: 6I5, variables: NGAS1,NGAS2,NGAS3,NGAS4,NGAS5,NGAS6

For exmple if only two gases are used slots 3-6 should be 77.
NGAS1 etc. gas number identifiers (between 1 and 80) see gas list below for identifying numbers. Use 77 for any unused slots

Third Card
Format: 8F10.4, variables: FRAC1,FRAC2,FRAC3,FRAC4,FRAC5,FRAC6,TEMP,TORR

FRAC1 etc. percentage fraction of gas1 etc.
TEMP temperature of gas in centigrade
TORR pressure of gas in Torr

Fourth Card
Format: 6F10.3, variables: EFIELD,BMAG,BTHETA

EFIELD electric field in Volt/cm
BMAG magnitude of the magnetic field in kilogauss;
BTHETA angle between the electric and magnetic fields in degrees

Fifth Card
Use NGAS=0 to terminate correctly.

Example of an input file:
2         5         0.0
2    8    77   77   77   77
90.0      10.0      0.0       0.0       0.0       0.0       20.0      760.0
3300.0    0.0       0.0
0

Running Simulation
This program is used to determine the diffusion parameters in gas samples. Currently the files used are in ~gmd/magboltz6/. In this folder are several example .output files, using ArCO2 90-10 and 80-20 gas at different E-field strengths. The input files are described above. Currently mag.input is used. The meaning of the numbers in the file are described above, be careful to leave decimal points if there already is one, and to keep the field widths for each number the same. (ie. if the old number was 45.2 and the new number 50, type in 50. or 50.0, and that the numbers all still line up). The only numbers that need usually be changed are the gas percentages, or the EField, the rest can remain the same (unless the gas type is changed).

The output files are labelled nicely. After running magboltz, these .output files are created. From the transverse and longitudinal diffusion, and the drift velocities, a drift distance vs. diffusion table can be created. An example of one is linked to above (under Magboltz results).

After saving the input file (eg. magboltz.input) the simulator is run from the ~gmd/garfield/ directory, or wherever you can find magboltz.run (or magboltz7.run):

magboltz.run < inputfilename.input > outputfilename.output - A path can be used in the filenames if your input and output files are not in the same directory as the program

This will save the output to the .output file which can be viewed at any time.

*NEW
You can use a script to run multiple simulations over a range of electric field values.

Currently found in ~gmd/garfield/, you can use either magrun.script for version 5.1 or magrun7.script for version 7.1

Form: magrun.script input maxval minval interval

< input > is an input file created as described above. The last three fields describe the desired maximum and minimum electric fields, with < interval > specifying the interval between each run (ie 50 would indicate going from max to min changing 50 V/cm each time).

Gas Codes
Argon = 2
Methane = 8
CO2 = 12
Click here for full listing of gases and the full page containing the above information .

Last updated October 3, 2004 - Dan Burke

Back

 
© 2006 Carleton University 1125 Colonel By Drive, Ottawa, Ontario, K1S 5B6 Canada (613) 520-7400